Description
CARRIER HD44AR135 BLOWER MOTOR 1/2HP 120/240V 7.7/4.3AMPS 1050 RPM EON 5.0 FRAME 39 CCW
Replaces: HD44AE132, HD44AE127, HD44AE124, HD44AE119, HD44AE129, HC44AE230, HD44AE132
Description
When looking for replacement motors, look no further than our Factory Authorized Parts (FAP)! FAP are designed to meet exact Carrier® Corporation specifications, ensuring optimum system performance, proven reliability, easy installation and maintenance and safe system operation.
FAP Features
• Improved Efficiency - Motor runs at most efficient portion of motor performance curve by design
• Ensures motor is not overloaded
• Ensures that motor operates at the design RPM, which produces the correct airflow
• Reduced System Vibration - System design put motor RPM at optimal point for limiting torque pulsations that can generate excess vibration in the unit
• Reduced Noise - System qualification includes additional testing such as start/stop and pure tone noise identification which further ensures there is not excessive vibration or noise during unit operation.
• Overall length of motor assures that fan is located at intended position to minimize sound and maximize airflow
• Reduced stress on components
• Natural frequencies of the top system are determined through design process.
• Motor operating frequencies are designed away from these resonances
• Reduced wear on system
• Motors tested to Temprise standard, stricter than required by UL 1995.
• Motors must meet maximum winding temperatures required by UL at higher ambient and wider voltage ranges (RES-SPL-CQR-0012A)
• Stringent design-life testing provides longer life 100,000 on/off cycles and 50,000 total running hours; 15 years.
• Reliability Testing Regimen - Each motor chassis design goes through internal and supplier testing including salt spray, torture, life, and operational envelope testing. (CC14BD002 and Alternating Current Fan Motor Standard)
• Raceway Connections - FAP motors have liquid tight connector for lead exit that connects to raceway.
• Wire Terminations and Lengths - Wire terminations are the same as production motors so no termination is necessary. Wire lengths reach required end points without alteration.
• Fewer On-site Modifications required - Fan guards and top covers are designed to accept FAP motors without modification.
• Exact size fit means easiest access.
• Few Hardware issues - Hardware used to mount and secure original motor can be used to mount replacement motor UL & CSA Qualified Both the CBP
Specifications
Weight......10.494 Pounds (lbs)
Width......5.5 Inches (In)
Height......9.9 Inches (In)
Country of Origin......MEX
Length......5.6 Inches (In)
Application......Provides exact drop-in replacement
Blower Motor HP......1/2 HP
Brand......RCD Parts
Comments/Notes......Meets exact design specifications for optimum system performance
CSA Listing......Yes
Cycle/Hertz......60 Hz
Full Load Amps......7.7,4.3
Motor HP......1/2 HP
NEMA Frame......39
Phase......Single
Prop 65......No
Ratings......Maintains agency listings and safety standards
Rotation......Counter-Clockwise
RPM......1050
Voltage......120/240 VAC
Specifications
Minimum Purchase: | 1 unit |
Manufacturer Part Number | HD44AR135 |
Manufacturer | Carrier |
Category | Furnace Parts |
Application | Blower Motor |